True Hazardous Location
Vacuum Oven Systems
How do we
achieve our hazardous location classification?
At Georgia
Oven Company we strive hard to ensure that our hazardous
location and or explosion proof vacuum systems are constructed
to meet or exceed the current codes set forth by the NFPA. We
achieve this by utilizing certified pressurization or purge
panel integration. These units come in three different
configurations depending on the classification requirements.
-
Type
X - Used in Class
I or II, Division 1, Groups A, B, C, D, E, F & G. These
units must disconnect power from the machine upon protective
pressure loss.
-
Type
Y - Used in Class
II Division 2, Groups E, F & G. These units must be
equipped with an alarm indicating protective pressure loss.
Power does not have to be disconnected. Type Y purges are
typically found in combustible dusts environments.
-
Type Z - Used in Class
I, Division 2, Groups A, B, C & D
We also use
intrinsically safe barriers and isolators in conjunction with
locating oven mechanics and heating sources in non hazardous
locations. "Intrinsically safe" products receive their
classification because their electrical power usage is below the
level of power required to set off an explosion within a given
hazardous area. In addition, "intrinsically safe'" products are
incapable of storing large amounts of energy which might spark
an explosion when discharged.
How do I
know what hazardous location is right for me?
This is
common question asked of us. Most of the time buyers or
equipment procurers will know what classification is expected of
them because they either have a building and or room rated for a
specific Class, Division and Group. But sometimes that is not
the case. One thing you have to understand is just because you
have bought an explosion proof piece of equipment does not mean
you can just put it anywhere in a factory and it is safe. These
units are only as good as its surroundings. If the area is not
rated at the same classification as the equipment then the
equipment is de-rated as well. The installation of this
equipment is the sole responsibility of the end-user or buyer.
Lets look at some of the more typical non classified
installations and there potential ratings:
-
Clean
Rooms - Most likely not classified but could potentially
carry a Class I, Div 2 rating
-
Laboratories - Typically use a Class I, Div 2 rating but
could be higher
-
General
Factory - Most likely unclassified
For instance
you do not need to buy an explosion proof oven for an area that
isn't rated for any Class or Division.
So what type
of Oven do I need to be safe in a non-rated room?
Well first
lets ask ourselves, do you really need a vacuum oven? or did you
think you needed a GOCI oven because it was rated explosion
proof ?
If the
answer is Yes then what you really want is a Class A Safety
Oven. These ovens are constructed for processing solvents and
or flammables under normal pressure at elevated temperatures.
There are many manufacturers of these ovens but we are not one
of them. Keep in mind when specifying these ovens that you know
how much solvent or flammables you are putting in the oven. A
good oven manufacturer will ask you and base the oven selection
on the LEL (Lower Explosive Limit) of the material.
No, I really
need a vacuum oven....Ok, typically if you have a non-rated room
and you need to process solvents and or flammables in a vacuum
then a Class I, Div 2 rated oven works great. It gives you an
element of safety similar to a Safety Oven but allows you to
process more because you do not need to worry about LEL (Lower
Explosive Limit) of the materials you are processing. This
would be our
Model
STX or
CNX.
Are there
other design considerations for Hazardous Locations?
Yes there is ..... you
should know that when specifying an oven for a classified areas
it is required by GOCI to know what type of materials or
substances will be processed. The flammable materials auto
ignition temperature regulates the maximum operating temperature
of the STX's heated surfaces. Once the auto ignition
temperature is known the oven will be assigned what is called a
T-code or temperature rating. It is a system developed by the
NEC or NFPA that indicates what the hottest surface could
potentially reach. Once a T-Code has been assigned to the oven
it will only be able to process solvents with the same or higher
auto-ignition temperatures. However it is possible to adjust
T-code ratings once the oven has been installed. This is
typically done by a factory trained individual.
|